Page 637 - Iscar
P. 637

USER GUIDE







                Drill diameter is adjusted with an adjust ball for diameter ø25 - ø39.99mm
                with the following method.                                                                           DEEP HOLE DRILLING















                                                              1.  Slide the dimensional guide pad forward and then
                                                                 retighten the lock screw at the measuring position.



                     Dimensional guide pad



                       Head body            Adjust ball


                                                Insert
                                                              2.  Tighten the adjust screw.


                                              Adjust screw

                                       Wrench

                                 Drill Dia. øDc




                                                              3.  As the adjust screw moves forward,
                                                                 insert moves peripheral direction.












                                                              4.  Measure the diameter with a micrometer. If the
                                                                diameter is larger than expected, loosen the adjust
                                                                screw and insert screw, then retighen the insert screw.
                                                                Repeat the procedure from step 2


                              Drill Dia. øDc














                                                                                                                  633
                                                                                                                  633