USER GUIDE
REAMERS Setting Procedure 2 3
1
Place the reamer between Use the pad as a reference for Rotate and place the inserts
the centering pins of the device. setting the indicator to zero. against indicators.
4 4 Adjust the frontal side of the insert
5
to: +15 µm (+0.6 µin) on D≤9.99,
+20 µm (+0.8 µin) on D≤10.00
6 Adjust the rear side of insert to:
+5 µm (+0.2 µin) on D≤9.99,
+10 µm (+0.4 µin) on D≤10.00
High Friction
Tighten the adjustment screws in a Lubricated Zones
clockwise direction.
Back Taper
The back taper prevents the reamer from jamming, as
well as lowering reaming forces and improving surface
quality. Incorrect back taper may cause unstable
reaming, accelerated wear and rough surface finish.
Insert Indexing
1 2
Rotate the adjustment screws one Rotate the clamping screw CCW from the
turn counterclockwise (CCW). top and/or clockwise (CW) from the bottom,
turning both sides simultaneously.
3
Remove the insert. Clean the insert and the pocket. Place
the sharp edge on the outer position.
Press the insert against the back stopper and the two
adjustment pins.
Tighten the clamping wedge by rotating the clamping
screw CW from the top or CCW from the bottom.
ISCAR
698 ISCAR
698