Page 551 - Iscar
P. 551
USER GUIDE
INDEXABLE DRILLS
4
3
1 2
5
Mounting Instructions
1. Insert the chamfer ring on the drill body NO
and slide to the desired position(1).
2. Rotate the ring clockwise until the stopper SETUP
engages the flute edge.
3. Tighten the ring screw according to the TIME!
maximum tightening torque indicated
on page 546.
4. Mount the chamfer insert.
5. Mount the CHAMDRILL head. Min. 1 mm
Chamfer Ring Position Range
Drill Body Drill Body Maximum
Drill 3xD 5xD Chamfer
Diameter L (min-max) L (min-max) Size
10 8-16 15-36
10.5 8-18 17-39
11 8-19 18-41
11.5 8-21 20-44
12 8-22 21-46 Min. 1 mm
12.5 8-24 23-49 1.5
13 8-25 24-51
13.5 8-27 26-54
14 9-29 28-57
14.5 9-30 29-60
15 9-31 30-60
16 9-33 32-65
17 11-35 34-69
18 11-38 34-74 2.0
19 11-42 41-80
20 11-45 44-85
User Guide
Recommendations for better stability:
1. Use 3xD drill instead of 5xD, if possible.
2. Mount the chamfer ring as close as possible 1mm (1)
to the drill shank.
3. For better chamfering insert life, apply a L
coolant to the chamfering insert, in addition
to the internal and/or external coolant.
4. A wider gap “X” between the drill and the head
size is preferred (i.e. for head 14.6 mm,
use body of 14 mm rather than of 14.5 mm).
A slightly larger “X” dimension can dramatically
increase the chamfering insert life.
(1) The “L” dimension shown is relative to the X
common 1 mm chamfer. (maximize)
5 For other sizes, adjust “L” accordingly.
547
547
547