Page 120 - CAMFIX
P. 120
l
HSK A-MAXIN
Power Chucks with HSK DIN69893 Form A Tapered Shanks A 0.003 A 58-60 HRc
Lmax
Lmin
D2 √N5
min
SS d2 D3 d max
L1Ref.
LRef.
Designation SS d2 (1) d min (2) D3 D2 L L1 L min L max Kg
HSK A 63 MAXIN 20X95 63 20.00 6.0 51.00 53.00 95.00 69.0 56.0 56.0 1.02
HSK A 63 MAXIN 32X113 63 32.00 6.0 69.00 70.00 113.00 87.0 70.0 85.0 1.32
HSK A 100 MAXIN 20X115 100 20.00 6.0 51.00 53.00 115.00 86.0 56.0 69.0 2.61
HSK A 100 MAXIN 32X110 100 32.00 6.0 69.00 70.00 110.00 81.0 70.0 78.0 2.72
HSK A 100 MAXIN 32X135 100 32.00 6.0 69.00 70.00 135.00 106.0 71.0 87.0 3.45
• A cooling tube must be used with all coolant through HSK spindles (should be ordered separately). • Use of dmax diameter tools provide best performance as
collets reduce gripping force by 25%.
(1) Without a collet (2) By using a reduction collet
For spare parts, refer to ISCAR TOOLHOLDING SYSTEMS catalog
l
KIT HSK A-MAXIN
Contains a Power Chuck with an HSK Tapered Shank and a SETS
Set of Collets in Various Bore Sizes
A 0.003 A 58-60 HRc
SS
SS
d2 d range
√N5
.
Designation SS d2 Qty d Range
KIT HSK A63 MAXIN20X95-6 63 20.00 6 6,8,10,12,14,16
KIT HSK A63MAXIN32X113-7 63 32.00 7 6,8,10,12,16,20,25
KIT HSK A100MAXIN20X115-6 100 20.00 6 6,8,10,12,14,16
• A cooling tube must be used with all coolant through HSK spindles (should be ordered separately). • Each kit contains one power chuck, a set of SC-SPR
collets, extraction hook and wrench.
120 ISCAR